California Analytical Instruments, Inc. (CAI) based in Orange, California has been a premier supplier of quality gas analyzers and systems for use in industrial, environmental, process, health & safety, and automotive emissions measurement applications for over 25 years. CAI's goal is to provide innovative, cost effective and reliable solutions. We believe there is no substitute for personal attention to the product requirements and support needs of our customers.
CAI utilizes technologies such as Chemiluminescence, Non-Dispersive Infrared (NDIR), Flame Ionization Detection (FID), Paramagnetic, FTIR, and Photoacoustic Infrared Spectroscopy (PAS) for measurement of CO, CO2, NO, NO2, N2O, NH3, O2, CH4, SO2, SF6, and HCL gases. CAI's computer controlled analyzers are currently installed in thousands of facilities in over a hundred countries.
|
|
|
|
- Product Features
- Technical Parameters
- Download
Online, real time reading
Fast response
%,PPM to PPb
Low maintenance
Low Cost Of Ownership
Intuitive user interface
Transportable
|
SPECIFICATIONS
DETECTOR: Chemiluminescence (CLD) Photodiode
(thermally stabilized with Peltier Cooler)
NO/NOx RANGES: 5 to 5,000 ppm NO/NOX
(Four user programmable ranges)
RESPONSE TIME: Typically < 2 seconds to 90% Full Scale
REPEATABILITY: Better than 0.5% of Full Scale
LINEARITY: Better than 0.5% of Full Scale
NOISE: Typically less than 1% of Full Scale
ZERO & SPAN DRIFT: Less than 1% of Full Scale per 24 Hours
ZERO & SPAN ADJUSTMENT: Via front panel, TCP/IP or RS-232
NH3 , HCN & SO2 EFFECT: Not detectable with 100 ppm
CO2 EFFECT: Less than 2.0% with 10% CO2
H2O EFFECT: Less than 0.8% total with chiller
FLOW CONTROL: Electronic Proportional Pressure Controller
SAMPLE FLOW RATE: Typically 1.5 to 2.5 LPM (0.6 LPM with low
flow option)
CONVERTER: Vitreous Carbon Material @ 205°C >95% efficiency
OZONATOR: Ultraviolet Lamp
AIR OR O2 REQUIREMENTS: Less than 0.01 ppm
NOX at 240 cc/Min. @ 25 psig (Dew Point < -10ºC)
NO/NOx CONTROL: Manual/Remote/Auto Cycle
OUTPUTS AVAILABLE: TCP/IP, RS232,
Four Scalable Analog 0-10 V / 4-20 mA
DISCRETE ALARMS: (Local & Remote Adjustable)
General Fault/ TTL Logic (Ground True)
Calibration Failure/ TTL Logic (Ground True)
High Concentration (2 each)/ TTL Logic (Ground True)
DIGITAL DIAGNOSTICS: Control Voltages, Temperatures,
Pressures, Flow Parameters
KEYPAD DISPLAYS: Factory Settings, TCP/IP Address,
Passwords (4), Scalable Analog Output Voltages,
Full Scale Range Select, Auto Cal Times
SPECIAL FEATURES: Calculated NO2 derived from NOX converter
efficiency, Auto Ranging, Auto Calibration (adjustable through internal
clock) Less than 3 cc Gold Plated Reaction Chamber
DISPLAY: 3” x 5” Back lit LCD
SAMPLE TEMPERATURE: Up to 50°C Noncondensing on CLD;
85-100oC on HCLD
OVEN TEMPERATURE: 85oC on HCLD; up to 100oC on request
AMBIENT TEMPERATURE: 5 to 40°C
AMBIENT HUMIDITY: Less than 90% RH Noncondensing
WARM-UP TIME: 1 Hour (Typical)
FITTINGS: 1/4 Inch Tube
POWER REQUIREMENTS: 115/230 (±10%) VAC; 50/60 Hz;
200 Watts (350 watts with pump)
DIMENSIONS: 5¼ H x 19 W x 23 D (Inches)
Weight: 45 lbs.
|
|
|
|
|
|