AMETEK, Inc. is a leading global manufacturer of electronic instruments and electromechanical devices with annual sales of approximately $5 billion. AMETEK has 18,000 colleagues at more than 150 operating locations, and a global network of sales, service and support locations in 30 countries around the world. The AMETEK Growth Model combines its four growth strategies of Operational Excellence, Strategic Acquisitions, Global & Market Expansion, and New Product Development, with a disciplined focus on cash generation and capital deployment. By executing the AMETEK Growth Model, the company seeks to generate shareholder value by doubling earnings per share over the course of each business cycle. AMETEK consists of two operating groups, both with highly-differentiated technology and leading positions in niche markets: Electronic Instruments - a worldwide leader in the design and manufacture of advanced analytical, test and measurement instrumentation for the energy, aerospace, power, research, medical and industrial markets. Electromechanical - a differentiated supplier of automation and precision motion control solutions, and highly engineered electrical interconnects, specialty metals and thermal management systems. Link::https://www.ametek.com/
  • Product Features
  • Technical Parameters
  • Download
• Monitoring natural gas pipelines and gas treatment processes
• Monitoring air humidity in dry boxes
• Continuous monitoring of atmospheres in simulated space chambers
• Sensing elements in humidity control systems
• Monitoring inert protective atmospheres in brazing or sintering furnaces
• Monitoring moisture in many fluorocarbon gases
• Constant measurement of batch and continuous driers to assure quality control without the expense of overdrying
• Monitoring anhydrous batch chemical processes at startup
• Quality control of transistor and diode backfill gas
• Instrument air systems
• Cryogenic processes
• Radar waveguides
• Dynamic Range: 0 to 1000 ppmv at 100 mL/min. sample flow through cell at 25OC and 101.4 kPa (0-2000 ppmv range possible with reduced sample flow)
• Sensitivity: 0.1 ppmv
• Accuracy: +0.5 ppm or +5.0% of the display reading, whichever is greater
• Response Time: 63% response to a stepwise change in either direction between 50 ppm and 1000 ppm will occur in 30 seconds or less
• Utility Requirements: 100 to 130 VAC or 200 to 260 VAC (select required model from table of Ordering Information on page 3) and optional 12 to 14 VDC* operation, 20 W maximum
• Analog Output: 4-to-20 mA DC proportional to range selected, compatible with 625-ohm maximum load
• Alarms: Rated for 1 A, 24 VDC, normally open and normally closed contacts; user-settable to fail-safe or low-power operation
• Sample Temperatures: up to 52OC (125OF)
• Ambient Temperatures: 0O to 52OC (32O to 125OF)
• Temperature Stability: 0.5% per OC of selected range
• Sample Pressure: 69 to 690 kPa (10 to 100 psi) gauge